ماژول کنترلر دما ورطوبت XY-WTH1
  • ولتاژ کاری : DC 6~30V
  • محدوده اندازه گیری دما: -20 ~ 60درجه
  • محدوده رطوبت: 0 ~ 100٪ RH
  • دقت کنترل: 0.1 ℃
  • اندازه: 71 * 39* 23میلیمتر

Product Features

Product functions are mainly classified into two categories :  temperature function and humidity function;

The temperature function is as follows:

  •  Automatic recognition of working mode


The system automatically recognizes the working mode according to the starting temperature / stop temperature;

Start temperature > stop temperature, cooling mode ' C ' ;  start temperature < stop temperature, heating mode ' H ';

  • Cooling mode


When the detected temperature ≥ the starting temperature, the relay is turned on, the red indicator light is on, and the cooling device starts to work;

When the detected temperature ≤ stop temperature, the relay is turned off, the red indicator light is off, and the refrigeration device stops working;

  •  Heating mode

      When the detected temperature ≤ the starting temperature, the relay is turned on, the red indicator light is on, and the heating device starts to work;

     When the detected temperature ≥ stop temperature, the relay is turned off, the red indicator light is off, and the heating device stops working.

  • Temperature correction function   OFE (-10.0 ~ 10.0 °C )


     If the system works for a long time, there may be deviations. Corrected by this function, the actual temperature =  measured temperature  +  calibration value;

How to set the start / stop temperature:

  1. In the running interface, press and hold the ' TM+ ' button for more than 3 seconds to enter the startup temperature setting interface. The test can modify the parameters through the TM+TM- key. After the parameters are modified, wait for 6s to automatically exit and save. 
  2. In the operation interface, press and hold the ' TM- ' button for more than 3 seconds to enter the stop temperature setting interface. The test can modify the parameters through the TM+TM- key. After the parameters are modified, wait for 6s to automatically exit and save.  


 

The humidity function is as follows:

  • Automatic recognition of working mode


Automatically recognize the working mode according to the starting humidity / stop temperature;

Start humidity> stop humidity, dehumidification mode ' d ' ;  start humidity <stop humidity, humidification mode ' E ' ;

  • Dehumidification mode


When detecting humidity ≥ start humidity, the relay is turned on, the green indicator light is on, and the dehumidification device starts to work;

When detecting humidity ≤ stop humidity, the relay is turned off, the green indicator light is off, and the dehumidification device stops working;

  • Humidification mode


     When detecting humidity ≤ start humidity, the relay is turned on, the green indicator light is on, and the humidifying device starts to work;

    When detecting humidity ≥ stop humidity, the relay is turned off, the green indicator light is off, and the humidification device stops working.

  • Humidity correction function RH (-10.0 ~ 10.0 °C )


   If the system works for a long time, there may be deviations. Corrected by this function, the actual humidity =  measured humidity  +  calibration value

 

How to set the start / stop humidity:


  1. In the operation interface, press and hold the ' RH+ ' button for more than 3 seconds to enter the startup humidity setting interface. The test can modify the parameters through the RH+RH- key. After the parameters are modified, wait for 6s to automatically exit and save. 
  2. In the operation interface, press and hold the ' RH- ' button for more than 3 seconds to enter the stop humidity setting interface. The test can modify the parameters through the RH+RH- key. After the parameters are modified, wait for 6s to automatically exit and save.

Operation interface description:

    The working mode shows that when the parameters such as starting temperature / humidity, stopping temperature / humidity are completed, the current mode ( “H/C” ,  “E/d” ) is displayed synchronously in front of the temperature / humidity


    Any one of the relays is turned on, and the upper left corner of the interface displays “OUT” . If the temperature relay is turned on, the temperature working mode “H/C” is flashing to indicate the reminder; if the humidity relay is turned on, the humidity working mode “E” is displayed. /d" to remind you

Other functions:

  •  Parameter remote read / set

     The parameters such as start temperature / humidity, stop temperature / humidity, temperature / humidity correction, etc. can be set through the UART

  • Temperature / humidity real-time reporting

     If the temperature / humidity reporting function is turned on , the product will detect the temperature / humidity and the state of the relay at  1 s intervals, and transmit it to the terminal through the UART to facilitate data acquisition

  • Relay enable ( default on )

If the relay is turned off, the relay remains off


How to modify the temperature / humidity correction value:


  1. In the operation interface, double-click the ' TM+ ' button to enter the correction value setting interface; the downlink display correction value type, the upper display specific value; ( OFE : temperature correction value RH : humidity correction value)    
  2. At this time, press the ' TM- ' key to switch the parameter to be modified , and modify the specific value by RH+RH- key; support long press and short press;  

  3. After the parameters have been modified, double-click the ' TM+ ' button to exit the correction value setting interface and save the data;  


How to turn on / off the relay enable switch:
      In the running interface, short press the ' TM- ' button to turn the temperature relay enable or disable (on : turn  OFF : off ) . After returning to the running interface, if the temperature relay is off, the temperature symbol '°C' flashes to Reminder.

      In the running interface, press the ' RH- ' button to turn the humidity relay enable or disable (on :  OFF : off ) . After returning to the running interface, if the humidity relay is off, the humidity symbol ' % ' flashes to Reminder.


 

Serial port control (microcontroller TTL level communication)

Communication standard : 9600bps  data bits : 8 stop bits : 1 check digit : none


 Temperature and humidity data upload format description

  • Temperature format: operating mode (H/C), temperature value, temperature relay status
  • Humidity format: working mode (E/D), humidity value, humidity relay status
  • H, 20.5 °C , CL: heating mode, current temperature 20.5degrees, temperature relay off state
  • D, 50.4%, OP: dehumidification mode, current humidity50.4% , humidity relay pull-in state

نوشتن نظر

لطفا برای ثبت نظر وارد حساب خود شده یا ثبت نام نمایید.

ماژول کنترلر دما ورطوبت XY-WTH1

  • مدل کالا: 1900593
  • موجودی: در انبار
  • 180,000 تومان
  • 175,000 تومان

برچسب ها: ماژول, کنترلر, دما, رطوبت, XY-WTH1, ماژولXY-WTH1, خرید ماژولXY-WTH1, قیمت ماژولXY-WTH1, خریدXY-WTH1, قیمتXY-WTH1, ماژول کنترلر دما و رطوبتXY-WTH1, راه اندازی ماژول XY-WTH1, کترلر دما و رطوبت, کنترلر دما و رطوبت برای جوجه کشی, XY-WTH1, راه اندازی XY-WTH1,

کالا در حال حاضر موجود نمیباشد.ایمیل خود را وارد نمایید، زمانی که کالا در دسترس باشد به شما اطلاع میدهیم.